Mode Control Panel
Glareshield - MCP 700/800/900
Vertical Speed (V/S) Switch

Push –

  • • arms or engages V/S command mode
  • • commands pitch to hold vertical speed
  • • engages A/T in speed mode to hold selected airspeed
  • • annunciates V/S pitch mode and illuminates V/S switch light.

Vertical Speed Command Mode

The V/S mode commands pitch to hold selected vertical speed and
engages A/T in SPEED mode to hold selected airspeed. V/S mode has
both an armed and an engaged state.
Engaged –

  • Annunciates V/S pitch mode.
  • Vertical speed display changes from blank to present vertical speed.
  • Desired vertical speeds can be selected with vertical speed
    thumbwheel.

V/S becomes armed if:

  • Pitch mode is ALT HLD at selected MCP altitude and
  • a new MCP altitude is selected (more than 100 feet from current
    altitude).

With V/S armed, V/S mode is engaged by moving vertical speed
thumbwheel.