Forward Overhead Panel  700/800/900
Display Selector
Ground Power and Bus Switching Panel
with associated APU Lights and Indicators
Click on the control or light for a description of its function.
Display Selector
Ground Power and Bus Switching Panel
with associated APU Lights and Indicators
APU GEN (APU Generator) Switch

Three position switch, spring–loaded to neutral.

OFF –
  • APU generator powering both AC transfer busses.










  • APU generator powering one AC transfer bus; IDG
    powering one AC transfer bus.
  • Moving a single APU GEN switch to OFF illuminates
    related SOURCE OFF light. APU continues to power AC
    transfer busses.

  • Subsequently moving other APU GEN switch to OFF
    disconnects APU generator from tie bus and removes
    APU power from  the AC transfer busses.
  • moving related APU GEN switch to OFF disconnects
    APU generator from tie bus and AC transfer bus. IDG
    powers AC transfer busses.
Next Page
(The APU Bus Switches cover two pages).
Generator 2 Switch
Next Page