Forward Overhead Panel 700/800/900
Ground Power and Bus Switching Panel with associated APU Lights and Indicators
|
Click on the control or light for a description of its function.
|
Ground Power and Bus Switching Panel with associated APU Lights and Indicators
|
APU OVERSPEED Light
Illuminated –
- APU RPM limit has been exceeded resulting in an
automatic shutdown.
- The overspeed shutdown protection feature has failed a
self–test during a normal APU shutdown
- If the light is illuminated when the APU switch is placed to
OFF, the light will extinguish after 5 minutes
- The light is disarmed when the APU switch is in the OFF
position.